securely seated with the sensor in contact with the
suction line. If working on a package unit make sure
you are at least 6 inches away from the compressor.
LL Pressure (liquid line pressure): Connect the
ASX14 to the liquid line service port. Set the acces-
sory head to measure pressure and ensure the read-
ing stabilizes before locking in the reading. Enter
data manually if you want to get pressure from your
gauges.  e analysis is only as good as the measure-
ments.  e Fieldpiece ASX14 has better resolution
than most gauge sets.
LL Temp (liquid line temperature): Measure near the
same location LL Pressure was taken. Use the ATC1,
ATC2 or ATC3 to get a good pipe temperature.  e
clamp should be perpendicular to the pipe and
should be securely seated with the sensor in contact
with the liquid line. If working on a package unit
make sure you are at least 6 inches away from the
compressor.
Condenser Air Enter Temp (Condenser Air En-
tering Temperature): Clip a calibrated ATA1 to the
inlet of the condenser  ns (typically on the side of
the condenser), in the shade if possible. Note that
the temperature of the air entering the outdoor coil
can be considerably di erent than the ambient tem-
perature due to recirculation of air exiting the unit.
Determine the average temperature of the air enter-
ing the condenser.
Cond Amps Draw (Condensing unit amp draw):
Actual amperage of the outdoor unit. For a package
system this will be the total amp draw of the unit.
is measurement must be taken with another me-
ter with an AC Amp clamp (such as the SC77) and
then input manually.
TrueFlow®
4
e TrueFlow® meter measures the air ow directly
via a grid installed in place of the  lter (or other location
that has all the indoor unit air ow through it).
4 TrueFlow® is the registered trademark of The Energy Conservatory.
TrueFlow®: Default: NO. If NO, skip ahead to the
Grant section. Answering YES unlocks the inputs
for this section.
Supply Plenum Press Without Grid: TrueFlow®
system operating pressure with the  lter installed
and no TrueFlow® grid.  is is the NSOP and is
measured using the static pressure probe included
with the TrueFlow® plate.
Grid Size: Default: 14 inches. Other selection: 20 inches.
Choose the grid size you are using.
Grid Pressure: is is the TFSOP and is measured
using the TrueFlow® plate.
GRANT
If you are working under a grant you must add ad-
ditional information about the system to qualify for the
grant. In parts of the United States,
CheckMe!® is used
to qualify for tax rebates and/or  nancial incentives.
ese programs have speci c requirements that will be
available in the HG2.
Residential and commercial air conditioning con-
stitutes about 15% and 33% peak of the electricity con-
sumed in this country. Utilities or regulatory commit-
tees o en o er grants to motivate consumers to save
energy.
In order to participate in these grants a technician
will usually have to work through a third party veri er.
Contact your local utility to learn on how to become a
grant participant.
Te st : Default: Initial.  e other selection is A er Re-
pair.
Grant: Default: None. Other selections will be avail-
able as grants are included. Some grants require dif-
ferent calculations.