5.802 Condensing unit amps unknown, check
condensing unit amps: e outdoor unit amp
draw was not measured.
5.803 High outdoor amp draw, probable exces-
sive compressor friction: Check other possible
causes of high amp draw (low condenser air ow and
refrigerant overcharge) before condemning the com-
pressor. Check that condenser coils and  ns are clean,
aligned and free of nearby obstructions.
5.804 Low outdoor amp draw, possible com-
pressor valve or motor problem: Check the re-
frigerant charge before condemning the compressor.
5.9 Cooling Capacity
e heat rejection at the outside unit is another mea-
surement that gives indication of the health of the com-
pressor as well as other potential problems.
5.901 Condesner capacity OK: e condenser is
delivering the proper capacity.
5.902 Low condenser capacity, check charge,
retest: is unit is rejecting less heat than expected.
Check the refrigerant charge, repair if needed, and re-
test.
5.903 Low condenser capacity, check compres-
sor amps and coil saturation temperatures:
Full diagnosis of this situation requires a complete set
of data including compressor amps, high and low side
pressures, and liquid and suction line temperatures.
5.10 Heat Pump in Heating
Test the refrigerant charge for a heat pump in the sum-
mer in the cooling mode if possible.  is procedure checks
the heating capacity of the heat pump against the expected
capacity for the test conditions. In order to determine the
capacity of a heat pump, the air ow through the inside
coil must be directly measured with the TrueFlow®.
5.1001 Heating Capacity OK: e heat pump is de-
livering the proper heating.
5.1002 Capacity unknown, check capacity: e
TrueFlow inputs, outdoor unit entering temperature,
return plenum temperature, and supply plenum tem-
perature need to be measured before determining ca-
pacity.
5.1003 Low capacity, defrost outside coil or ad-
just charge and retest: Verify that the outside coil
is not frosted or iced. Frost reduces the capacity of the
heat pump. If the unit is not frosted, adjust the refrig-
erant charge per the manufacturer’s speci cation.
5.1004 High temp split, make sure strip heat is
NOT on: Check amperage to the electric strip heat-
ers to verify they are turned o .