1.3 Target Evaporator Exit Temperature
OUTPUT FORM
Figure 5. OUTPUT FORM for Target Evaporator Exit Temperature.
Press OUTPUT for the Target Evaporator Exit Tem-
perature OUTPUT FORM.
Target Evap Exit DB Temp (Target Evaporator
Exit Dry Bulb Temperature):  is is the target exit
temperature based on the measured indoor condi-
tions.
Actual Evap Exit DB Temp (Actual Evaporator
Exit Dry Bulb Temperature):  is is the measured
temperature of the air in the supply.
e
Actual Evap Exit DB Temp should be
within ±3°F of the
Target Evap Exit DB Temp. If
the temperature is outside of this range, the technician
should make modi cations to correct the problem.
1.2 Target Evaporator Exit Temperature
INPUT FORM
Figure 4. INPUT FORM for Target Evaporator Exit Temperature.
Into Evap Return Dry Bulb and Wet Bulb: Take
measurements as close to the inlet of the air handler
as possible. If the  lter is just before the air handler,
the easiest way is to clip an ATWB1 and ATA1 to the
lter on the side facing the evaporator and take the
measurements. If the  lter is not before the evapo-
rator, make small holes in the return plenum just big
enough for the probes. Seal any holes before leaving
the jobsite.
Out of Evap Supply DB (dry bulb temp leaving
the evaporator): Measure in the center of the supply
plenum. Punch a small hole in the supply plenum
and insert a calibrated dry bulb thermocouple such
as the ATA1 or ATB1. Make sure the thermocouple
is in the center of the plenum cross-section. Seal the
hole when  nished.
Can be measured automatically with
Fieldpiece accessory heads.
Units can be changed to either English
or Metric.
Customer ID is useful for record keeping.
Sections of manual with more
information about this test.
If Target and Actual are more than 3°F
apart a modification is needed.
An Actual Evap Exit DB Temp above the
Target Evap Exit DB Temp usually indicates low
capacity. Occasionally air ow is higher than expected.
Look for causes of low capacity such as refrigerant mis-
charge or dirty condenser coil. If the air ow is high,
correct by lowering the fan speed.
Because everything within the system is inter-de-
pendent, one adjustment can a ect other parts of the
system. For example, increasing air ow increases the
superheat, which may require adding refrigerant. A er
modi cations, allow 15 minutes to stabilize and then
retest.
An Actual Evap Exit DB Temp below the
Target Evap Exit DB Temp indicates low air ow.
Increasing air ow can be accomplished by elimi-
nating restrictions in the duct system, increasing blower
speed, cleaning  lters or opening registers. A er cor-
rective measures are taken, repeat measurement proce-
dures as o en as necessary to establish adequate air ow
range. Allow system to stabilize for 15 minutes before
repeating measurement procedure.